Pre-Terminated Fibre Optic Cabling

ST & SC Standard Connector options - other connector types on request

Fibre Counts of 4, 8, 12 & 16

Fast Manufacturing Lead Times

Low Installed Cost

50/125, 62.5/125 or Singlemode Fibre

Fibreco manufactures a low cost pre-terminated cabling solution, which combines the benefits of using standard connectors and tight buffered cable with greatly reduced installation times.
These high quality factory terminated cables may be used for simple point to point links or to install a complete fibre optic network. The cabling is fully compatible with all standard cable management accessories and requires no special tools or expertise to install.
The cables are fitted with a gland and special pulling head, which is attached to the cable strength member. This fully protects the connectors during installation and allows the cables to be pulled through ducts without applying load to the terminations.
Fibreco pre-terminated cabling is fully tested in the factory and is supplied with an attenuation test certificate and installation instructions.

Outline Specifications

Connector Performance:
Multimode Singlemode
ST, SC & LC Connectors ST, SC, LC & FC Connectors
Insertion Loss Insertion Loss Return Loss
Typical <-0.3dB Typical <-0.2dB SPC: >45dB
Maximum -0.5dB Maximum -0.4dB UPC: >55dB
Spacing Spacing Spacing Spacing APC:>60dB

Cable Characteristics: Tight Buffered internal / external specification
Fibre
Count
Cable
Dia (mm)
Weight
(kg/km)
Sheath
Material
Min Bend
Radius
Installation
Tension
Crush
Resistance
Operating
Temp (°C)
4 5.5 26 LSZH 55mm 800N 300N/cm -20 to +60
8 6.0 32 60mm 900N
12 6.5 40 65mm 1000N
16 7.5 47 75mm 1200N

Multimode Fibre Characteristics:
Fibre Type Attenuation dB/km Bandwidth MHz/km NA
850nm 1300nm 850nm 1300nm
62.5/125 3.5 1.5 200 500 0.27
50/125 OM2 3.0 1.0 500 800 0.20
50/125 OM3 3.0 1.0 1500 500 0.20

Singlemode Fibre Characteristics:
Attenuation dB/km Dispersion ps/nm.km
1310nm 1550nm 1310nm 1550nm
9/125 0.40 0.28 3.5 18.0

Pulling Head Characteristics
Maximum Diameter: 28mm
Maximum Tensile Load: 1000N
A Swivel and appropriate Fuse Pin must be used when pulling through ducts